Digital Scale Series

| Home | Instructions | Scales |

 

User Manual

I. Function of a.
● Switch function
● Weight unit conversion function
● Precision correction function
● The function of calculating the total quantity or number
● Reset or peel function

II. Key description
/ switch: switch the local power button
M unit: unit selection key / precision correction key
PCS count P: function key to calculate quantity
T clear: clear the data of the display screen, display 0.0/0.00

III. Functional operation instructions
This product should be used on the horizontal surface without vibration.

1. switch:
Short press the [switch ] power button to open the machine. The display screen displays "HELLO" and returns to the zero position "0.00" or "0.0". The machine can be used normally. The Settings of automatic shutdown and manual shutdown are as follows:
In the boot state, long connect [T] or [reset] key will display for 60 seconds, then press [M] or [unit] key to select 120 seconds, 180 seconds and 0 seconds. 0 seconds is no time control and manual shutdown is required. After selecting the required shutdown time, then connect [switch ] to display PASS to confirm completion.

2. M / unit:
Short press [M] or [unit] button to select unit conversion. There are 9 unit modes to choose from: grams, kilograms, grains, ounces, carats, milliliters, pounds, Jin and Liang. Press this button to find the unit symbol you need at the top of the display screen.

3. T / reset:
Clear the number on the display screen, or place a tray or container on the scale table after pressing the "T" or "clear" button. The display screen will display "0.00" or "0.0" and then place the required add-on. The exact weight of an item can be obtained by weighing it in a container or tray.

4. PCS / count / P
Prerequisite for using the counting function: each item to be counted must be the same weight. As mentioned on long press "PCS" / P counting ] key, display shows the sampling values can then press [M/unit] key to switch to the required sampling values, numerical 25,50,60,75,100, then according to the selected numerical put an equal amount of sample on the scale and short press "PCS", again "count" / P key confirmation to complete sampling, and then began to count, to need to count items into the scales on the stage, display shows the exact number of items, in the counting process short press [ M / unit and PCS / P counting ] key to switch between weighing and counting. So that you can get weight as well as quantity.
Note: the counting function can be realized by placing the items to be sampled on the scale platform before operation, or selecting the sampling data and then placing the items on the scale platform.

5. Accuracy correction
Before delivery of this product has been completed correction, such as the normal weighing of the product or when weighing inaccurate please re-correct on long press press [M / unit to monitor before delivery or last school machine weights weight value, if there is no current weight value weights please continue to press to choose the appropriate weights M, the unit ] [weight value, finished, please press the "switch" key display shows "CAL screen will then display calibration weights weight value in flashing, the corresponding method of weight to the middle of the weighing platform location pattern, and then switch/display correction PASS ] [switch / ] is complete, the product back to the normal state of weighing. The calibration is completed and the normal use is carried out. In order to make the electronic scale reach the most accurate, the user should try to select the calibration machine with the maximum value. If "OUT2" is displayed when the product is turned on, please refer to the following correction method to re-calibrate the product.
Turn off the product that has been turned on. At the same time, press and hold the [switch / ] button and the [M / unit] button to display a set of weight values. Then press [M / unit] to select the maximum scale value of the electronic scale that you currently purchase. Chosen and then press [switch / ] show a row number then display "CAL" switch / ] [school machine weights weight value in the flicker, the corresponding method of weight to the middle of the weighing platform location pattern, and then switch/display correction PASS ] [switch / ] is complete, the product back to the normal state of weighing, correction complete bring weight down to normal use.

6. Troubleshooting:
The main reasons for inaccurate weighing and failure include: low battery power, incorrect calibration, weighing items beyond the maximum range of the product.
Or not operating on a horizontal surface, etc.
A display of "LO" indicates that the battery needs to be replaced.
Display "o-ld" indicates overweight, please remove the weight immediately, otherwise it will crush the sensor.
When power on, the charging display of "CHAR" will resume weighing after 3-5 seconds. When power off, the charging display of "CHAR" will resume weighing after 3-5 seconds. When power off, the charging display of "CHAR" will resume weighing after 3-5 seconds.
The display "FULL" is in the state of FULL charge, which can be fully charged within 1 hour under normal environment.